Description: 18L Steam Sterilizer High Pressure Autoclave Lab Dental Equipment
This listing is for a brand new portable stainless steel pressure 18L steam sterilizer which is one of best in the same grade sterilizer. It uses saturated steam to rapidly and efficiently sterilize articles.
Application:
This 18L steam sterilizer can be used in hospitals, public health centers, health stations, clinics in factories and mines and scientific research institutes, etc, to sterilize medical equipment surgical dressings and glass utensiles, etc. high pressure autoclave can also be used as a cooker in plateaus areas and make high quality drinking water in the industrial and mining enterprises.
Features:
1. CE.ISO9001 Certificated
2. Heated by immersed electro-thermal tube, it features quick temperature rise and low power consumption(saving about 50% of energy compared with electric stove).
3. Iron flange reinforcement thickening pot body coal and electricity dual purpose.
4. This autoclave can also use liquefied petroleum gas and coal stove as the heating energy.
5. Container is made up of medical stainless steel. It is not only alkali & acid proof but also 3 times more tensile and compressive than aluminum allyoy, ensuring safety and service life.
6. The lid is equipped with safety valve and air releasing valve, as well as a pressure gauge with mega-bar and temperature readings for convenience of the user.
How to Use:
1. Place the sterilizer on the flat surface;
2. Open the lid, take out the inner tank of sterilizer(you can see the heating electric tube), add water to the heating tube above 3.5L, you must add enough water in time to avoid burning the electric tube due to a lack of water;
3. Put those items needed to sterilize into the sterilization room, you should keep gaps between the items. Do not block steam holes of the safety valve and air releasing valve, and finally cover the lid, tighten the screws;
4. After the normal operation of the equipment, when the measured temperature reaches 105°C, open the air releasing valve to discharge cold air inside the sterilizer. When the air releasing valve starts going out a little hot steam, close the air releasing valve;
5. When the steam pressure reaches 0.14-0.16MPa , the safety valve will start pressure relief work, in order to maintain a certain pressure;
6. After sterilization, unplug the power cord. 3 minutes later, open the air releasing valve, when the pressure gauges indicates zero, open the lid to discharge the remaining air.